45° ST A Holders
Left Hand
Right Hand
h
b
L
hmax
1600-08x100 45 ST LA
1600-08x100 45 ST RA
8
8
100
2
1600-10x80 45 ST LA
1600-10x80 45 ST RA
10
10
80
2
1600-10x100 45 ST LA
1600-10x100 45 ST RA
10
10
100
2
1600-12x100 45 ST LA
1600-12x100 45 ST RA
12
12
100
2
1600-16x125 45 ST LA
1600-16x125 45 ST RA
16
16
125
2
1600-3/8”x80 45 ST LA
1600-3/8”x80 45 ST RA
9.525
9.525
80
2
1600-3/8”x100 45 ST LA
1600-3/8”x100 45 ST RA
9.525
9.525
100
2
1600-1/2”x100 45 ST LA
1600-1/2”x100 45 ST RA
12.7
12.7
100
2
1600-5/8”x125 45 ST LA
1600-5/8”x125 45 ST RA
15.875
15.875
125
2
Note: With these combinations of holder and insert, radial and axial undercuts can be turned with standard inserts 1604...Sp up to a limited depth,
90° Holders
Left Hand
Right Hand
h
b
L
Dmin
1600-10x100 90 L
1600-10x100 90 R
10
10
100
17
1600-12x100 90 L
1600-12x100 90 R
12
12
100
17
Note: These Holders Require Opposite Insert (ie: Right hand holder uses left hand insert!) These holders require 1699 series inserts - refer to the full Multidec® Catalog for details
90° ST Holders
Left Hand
Right Hand
h
b
L
hmax
Dmin
1600-10x100 90 ST L
1600-10x100 90 ST R
10
10
100
4
21
1600-12x100 90 ST L
1600-12x100 90 ST R
12
12
100
4
21
1600-16x125 90 ST L
1600-16x125 90 ST R
16
16
125
4
21
Note: These Holders Require Opposite Insert (ie: Right hand holder uses left hand insert!)
90° ST A Holders
Left Hand
Right Hand
h
b
l
v
w
hmax
1600-08x80 90 ST LA
1600-08x80 90 ST RA
8
8
80
17
15
4
1600-08x100 90 ST LA
1600-08x100 90 ST RA
8
8
100
17
15
4
1600-10x80 90 ST LA
1600-10x80 90 ST RA
10
10
80
17
15
4
1600-10x100 90 ST LA
1600-10x100 90 ST RA
10
10
100
17
15
4
1600-12x100 90 ST LA
1600-12x100 90 ST RA
12
12
100
17
15
4
1600-16x125 90 ST LA
1600-16x125 90 ST RA
16
16
125
17
16
4
1600-20x125 90 ST LA
1600-20x125 90 ST RA
20
20
125
17
20
4
1600-3/8”x80 90 ST LA
1600-3/8”x80 90 ST RA
9.525
9.525
80
17
15
4
1600-3/8”x100 90 ST LA
1600-3/8”x100 90 ST RA
9.525
9.525
100
17
15
4
1600-1/2”x100 90 ST LA
1600-1/2”x100 90 ST RA
12.7
12.7
100
17
15
4
1600-5/8”x125 90 ST LA
1600-5/8”x125 90 ST RA
15.875
15.875
125
17
15.875
4
1600-3/4”x125 90 ST LA
1600-3/4”x125 90 ST RA
19.05
19.05
125
17
19.05
4
90° RD Coolant-Thru Holders
Left Hand
Right Hand
d
L
hmax
Dmin
1600-12x125 90 RD L IC
1600-12x125 90 RD R IC
12
125
3
17
1600-16x150 90 RD L IC
1600-16x150 90 RD R IC
16
150
3.5
21
1600-20x180 90 RD L IC
1600-20x180 90 RD R IC
20
180
4
25
Note: These Holders Require Opposite Insert (ie: Right hand holder uses left hand insert!)
GenSwiss 2019 Catalog
Utilis 2020 Catalog
GenSwiss REACH Compliance Declaration